Franca, André CabralSouza, Itamar Ferreira deAlves, Luis Wagner RodriguesJesus, Adriana Madeira SantosEmbrapa - Café2015-01-142015-01-142007França, André Cabral; Souza, Itamar Ferreira de; Alves, Luis Wagner Rodrigues; Santos, Adriana Madeira Santos. Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de clorofila em cafeeiro. In: Simpósio de Pesquisa dos Cafés do Brasil (5. : Águas de Lindóia, SP : 2007). Anais. Brasília, D.F. : Embrapa - Café, 2007. (1 CD-ROM), 3p.179995_Art005http://www.sbicafe.ufv.br/handle/123456789/2432Trabalho apresentado no Simpósio de Pesquisa dos Cafés do Brasil (5. : 2007 : Águas de Lindóia, SP). Anais. Brasília, D.F. : Embrapa Café, 2007.O objetivo do trabalho foi calibrar o medidor indireto de clorofila Minolta SPAD-502, para quantificação de clorofilas em folhas de cafeeiro cultivar Topázio, baseando-se na comparação das leituras de clorofila com teores obtidos pelo extrator acetona 80% (Arnon, 1949). Folhas de cafeeiro, da cultivar Topázio (MG -1190), foram retiradas durante o mês de março de 2006, com variação das tonalidades, do verde amarelado ao verde escuro intenso. No laboratório foram retirados quatro círculos do terço médio de cada folha de área de 346 mm², e submetido a leituras com o SPAD-502. Foram então armazenados em cadinho com 20 ml de solvente (acetona 80%). Após macerado e filtrado, o material foi inserido ao espectrofotômetro, efetuando-se a leitura de absorbância (663 e 645 nm). As leituras efetuadas pelo SPAD-502 se correlacionaram com as determinações dos teores de clorofila a, b e total de acordo com as equações: Ca y = -1,841723 + 0,221183x (R² = 96,7%); Cb y = 0,929354 + 0,064933x (R² = 96,9%); e Ct y = -0,915272 + 0,286493x (R² = 96,23%), respectivamente, no qual a variável independente (x) representa as leituras analisadas pelo aparelho Minolta SPAD-502, que detêm de leituras indiretas de clorofila.The objective of this work was to calibrate SPAD-502 adjusting readings to the equations of chlorophyll a, b, total of coffee plant leaves determined by acetone extraction (Arnon, 1949). Green intensities, varying from green-yellowish to dark green, of coffee leaves were harvested in March 2006. Disks of 346 mm2 were extracted from each leaf and inserted into SPAD –502. After reading they were homogenated with 20 mL acetone in a melter pan, filtered, and the absorbance at 663 and 645 nm were read in a spectrophotometer. SPAD-502 readings were well correlated with calculated chlorophylls a, b, and total according to equations: Ca y = -1.841723 + 0.221183x (R² = 96,7%); Cb y = 0.929354 + 0.064933x (R² = 96,9%); e Ct y = -0.915272 + 0.286493x (R² = 96,23%), respectively, in which the independent variable (x) it represents the readings analyzed by the apparel Minolta SPAD-502.pt-BRLeituras indiretas Clorofilímetro Coffea arabicaIndirect readings Chlorophyll meter Coffea arabicaCafeicultura::Agroclimatologia e fisiologiaCalibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de clorofila em cafeeiro[Calibration chlorophyll meter Minolta SPAD-502 for evaluation of the content of cholorophyll in coffee tree][Calibration chlorophyll meter Minolta SPAD-502 for evaluation of the content of cholorophyll in coffee tree]Artigo